TY-BNC-H
Category:SPD for coaxial
BNC Connector Antenna Signal Lightning Protector
Tel:+86-577-62605321
Email:andy.xu@tycotiu.com
PDF DownloadFeatures:
Comply with IEC61643-21 standard
Large capacity, multi-level protection
Characteristic impedance:50Ω
Protection level:IP20
Insertion loss:≤0.3dB
Connectiion:BNC
Parameters:
Model
TY-BNC-H
Test standards
IEC 61643-21
Max. continuous operating voltage
Uc
180VDC / 130V AC
Nominal current
IL
20A
Voltage protection level [line-shield/PG]
Up
≤800V
Operating temperature range
Tu
-40℃-80℃
Connection input / output
BNC
Enclosure material
Steel
Degree of protection
IP20
C2 Nominal discharge current (8/20μs)[line-shield/PG]
In
10kA
Response time [line-shield/PG]
tA
≤100ns
Bandwidth
3 Gbps
Insertion loss
≤0.3dB
Impedience
50Ω
Application:
Mainly used for the protection of equipment along the video signal line, such as video surveillance equipment (camera, video monitor, optical terminal, display, cable TV, home TV, etc.)
Prevent the surge invading the equipment along the feeder and causing damage
Installation and Maintenance:
Install in series in front of the protected equipment (or system),install as close to the protected equipment (or system) as possible.
The input end of the lightning protection device is connected with the signal line, and the output end is connected with the protected equipment, which can not be connected in reverse.
The PE grounding wire of the surge protector must be connected with the grounding system reliably, and the connecting wire should be short, thick and straight.
The product does not need special maintenance, Install as close to the device end as possible; When the work system failure, can be removed the lightning protection device, if system restored to the state before the use of normal, it should be replaced lightning protection device.